Optimization of Fastening of AAC (Autoclaved Aerated Concrete) Structures When Filling External and Internal Walls of Frameworks of Buildings of up to 80 m Height

Number of journal: 8-2015
Autors:

Mordvov A.A.
Likhtarovich M.V.

DOI: https://doi.org/10.31659/0585-430X-2015-728-8-26-29
УДК: 691.327.332:692.23

 

AbstractAbout AuthorsReferences
Developers of normative documents, which regulate the use of autoclaved aerated concrete, faced the problem of the absence of experimental studies. As a result of this, documents contain a large number of elements and requirements which were executed with a large reserve according to the well-established practice of applying. The tests of structures conducted at SIBIT factory will make it possible to revise some of these «reserves» that under conditions of market competition will favor the improvement of competitive advantages of aerated concrete.
A.A. MORDVOV1,2, Candidate of Sciences (Engineering), Chief Architect
M.V. LIKHTAROVICH1, Engineer, Head of Technical Support Department (This email address is being protected from spambots. You need JavaScript enabled to view it.)

1 «Glavnovosibirksstroy» OAO (52a 2nd Stantsionnaya Street, 630041, Novosibirsk, Russian Federation)
2 Novosibirsk State University of Architecture and Civil Engineering (113, Leningradskaya Street, 630008, Novosibirsk-8, Russian Federation)

1. Standard of Organization NAAG 3.1–2013. Designs using autoclaved gas concrete in the construction of buildings and structures. Rules of design and construction. St. Petersburg. 2013. 171 p. (In Russian).
2. Gorshkov A.S. Stability conditions simply supported by floor walls made of porous concrete masonry units, taking into account the exposure to wind loads. Proceedings of the SPC “Modern autoclaved gas concrete”. Krasnodar. 2013. 186 p. (In Russian).
3. GOST 31360–2007. Wall unreinforced products of cellular autoclave curing concrete. Technical conditions. M.: Standartinform. 2008. 20 p. (In Russian).
4. SP 20.13330.2011. Loads and effects. The updated edition of SNiP 2.01.07–85*. Moscow. 2011. 81 p. (In Russian).

For citation: Mordvov A.A., Likhtarovich M.V. Optimization of Fastening of AAC (Autoclaved Aerated Concrete) Structures When Filling External and Internal Walls of Frameworks of Buildings of up to 80 m Height. Stroitel’nye Materialy [Construction Materials]. 2015. No. 8, pp. 26-29. (In Russian). DOI: https://doi.org/10.31659/0585-430X-2015-728-8-26-29


Print   Email